Twin wall polycarbonate stocked by the pallet in Sparks, NV. 6mm and 8mm clear in 4x8 and 4x10, H and U profiles on the shelf, cut to size with free local delivery.
Twin wall polycarbonate is two skins joined by internal ribs, so a single sheet gives you daylight, insulation, and impact strength at a fraction of the weight of glass. It cuts with a circular saw, cold-bends without heat, and carries a 10 year warranty. We stock it by the pallet in Sparks and sell whatever you need out of it — one sheet or a hundred. Weighing it against solid polycarbonate sheet? We put the two side by side.
| Thickness | Edge on, to scale | Structure | Color | Sheet sizes in stock |
|---|---|---|---|---|
| 6mm (1/4″) | 2-wall | Clear | 48″ × 96″ · 48″ × 120″ | |
| 8mm (5/16″) | 2-wall | Clear | 48″ × 96″ · 48″ × 120″ |
The panel is drawn edge-on at the same scale as every other thickness on the site, and drawn hollow because that is what it is — two skins with air and ribs between them. That air is the insulation; it is also why a 6mm panel weighs a fraction of what 1/4″ solid sheet weighs.
We buy this by the truckload and carry it in pallet quantities — hundreds of sheets of 8mm on the rack at any given time. That depth works both ways. Forty sheets on Thursday is a phone call rather than a lead time, and one sheet cut to size for a shed door is off the rack the same day. There is no pallet minimum. H-profiles and U-profiles are stocked for both 6mm and 8mm, so you are not waiting on connectors after the panel shows up either.
| Color | Thickness | Sheet | Regular | Sale |
|---|---|---|---|---|
| Clear | 6mm | 4×8 | $100 | $75 |
| Clear | 6mm | 4×10 | $129 | $96.75 |
| Clear | 8mm | 4×8 | $109 | $81.75 |
| Clear | 8mm | 4×10 | $139 | $104.25 |


Stock covers most jobs. When it doesn’t, here is the honest picture rather than a maybe:
Anything larger than 48″ × 120″ runs a 4 to 6 week lead time and carries freight. We will tell you that before you spec it, not after you have committed to a schedule.
Twin wall is a dry-fit system. The panel is half the job; the connectors are the other half, and they are the part people forget to order.

Two details that cause most callbacks: flutes must run vertically on a wall and with the slope on a roof so water drains, and you need roughly 1/8″ of expansion clearance per 4 feet of panel. Pre-drill holes larger than the fastener and do not overtighten — a crushed washer is a leak.
Gallina PoliCarb® 2-wall sheet, from Gallina USA. These are the two configurations we stock.
| Property | 6mm (1/4″) | 8mm (5/16″) |
|---|---|---|
| Structure | 2-wall | 2-wall |
| Weight | 0.266 lb/ft² | 0.307 lb/ft² |
| U-value (R = 1/U) | 0.61 (≈ R-1.6) | 0.58 (≈ R-1.7) |
| Visible light transmission, clear | 80% | 81% |
| Solar heat gain coefficient, clear | 0.80 | 0.82 |
| Shading coefficient, clear | 0.91 | 0.94 |
| Minimum cold bend radius | 39″ | 59″ |
| Flame spread | ASTM E84 Class A on request | ASTM E84 Class A on request |
| Burn rate | ASTM D635 CC1 | ASTM D635 CC1 |
| UV protection | Coextruded, exterior face | Coextruded, exterior face |
| Warranty | 10 year | 10 year |
NFRC test data may vary from published data. Bronze and opal run lower on light transmission — 42% and 57% respectively at these thicknesses. The fire figures are Gallina’s published classifications, which is not the same document as an E84 test report — tell us which one your submittal needs and we will get it.
Three charts that cover the reason anyone specifies twin wall instead of glass or solid sheet. Twin wall figures are Gallina’s published data for the 2-wall sheet we stock; the glass and solid-sheet comparisons are typical published values, marked as such.
This is the chart that decides most jobs. At the same 1/4″ thickness, twin wall weighs about a twelfth of glass and about a sixth of solid polycarbonate. That changes the structure you have to build under it, the crew you need to hang it, and whether a canopy or a containment panel needs an engineered frame at all. The ribs are why — you are buying two thin skins and air, not a solid slab.
Twin wall is about 70% better than single-pane glazing (R-1.6 against R-1.0) and reaches roughly 80% of an uncoated sealed double-pane unit — at a twelfth of the weight, without a frame rated to carry glass, and without a sealed edge that can fail and fog. Two things we will not pretend: it does not beat an IGU on U-value, and a modern low-E argon unit hits about U-0.24, far better than anything else on this chart. Twin wall wins on weight, impact, span and cost, not on insulation alone.
Clear passes 80% of visible light but diffuses it through the ribs, so you get daylight without the hot spots and glare you get through clear glazing. That is the whole point in a greenhouse or a containment aisle. Bronze at 42% is the one to specify when solar heat gain or glare is the actual problem rather than light level.
Grades marked In stock are on the rack in Sparks; the rest we bring in to order. The sheet you download is the sheet we quote from.
Purlin and rafter spacing depends on your snow and wind load, the sheet thickness, and the span — there is no single right answer, and a table on a website is a good way to get it wrong. Send us your span, spacing, and design load and we will pull the manufacturer’s load chart for your configuration before you commit to a framing layout.
Polycarbonate expands at 0.065 mm per meter per °C. Gallina publish two different working rules in two different documents, and they do not agree:
We tell people to build to 1/8″ per 3 feet per 100°F, and 1/4″ per 4 feet in bronze. Northern Nevada goes from a January night to a July roof deck — a 100°F swing is not a worst case here, it is a Tuesday. An oversized gap costs nothing. An undersized one buckles the panel or tears out a fastener, and you will not find out for a year.
On slope: Gallina call for a minimum of “7% or 5°” for drainage. Those are not the same number — 7% is about 4°, and 5° is 8.75%. Build to 5° and you satisfy either reading of their spec. Build expansion and slope into the frame, not into the fastening.
Polycarbonate handles most of what it meets in normal service, but a few common shop and janitorial chemicals will ruin a panel. This is the part that gets a sheet replaced a year early.
| Exposure | Effect on polycarbonate |
|---|---|
| Machine oil, paraffin oil, silicone oil | No change |
| Kerosene, diesel, n-heptane | No change |
| Ethyl alcohol 50%, most organic acids | No change |
| Sodium chloride, sodium carbonate 10% | No change |
| Ammonium hydrate 10% — most glass cleaners | Browning |
| Methyl alcohol, triethanolamine | Cracking |
| Methyl ethyl ketone (MEK), styrene | Clouding and softening |
| Benzol, toluol, acrylonitrile | Rapid dissolution |
| Industrial petrol, phenol | Yellowing, cracking, opacification |
| Sulphuric acid 70%, nitric acid | Yellowing |
Clean it with warm water, mild dish soap, and a soft cloth. Nothing else. Ammonia-based glass cleaner is the single most common way a good panel gets ruined — it browns the surface and there is no fixing it. No abrasives, no solvents, no squeegee on a dry panel. Source: Dott. Gallina chemical resistance data, used with permission. For aggressive or unusual exposure, tell us the chemical and we will check compatibility before you buy.
We cut twin wall to your dimensions in our Sparks shop so it arrives ready to install — no measuring and cutting on a windy roof. Panels can be cut, drilled, and profiled here, and we blow the flutes clear before they leave. Cut-to-size and custom fabrication are done in-house, and delivery is free in Reno, Sparks, Carson City, Fernley and USA Parkway. If your site is out on USA Parkway, that is a short run for our van.



Insulation and span. The 8mm is slightly warmer (U-0.58 vs U-0.61) and stiffer, so it handles wider purlin spacing and more load. The 6mm is lighter and cheaper and bends tighter — a 39″ minimum radius versus 59″ for the 8mm. For most canopies, greenhouses, and partitions, 8mm is the safer default. For tight curves, 6mm.
No. We stock it by the pallet so it is always here, but we sell it however you need it — one sheet, five sheets, or the whole pallet. We will also cut a single sheet down to your dimensions. The deep stock is there so you are not waiting on a truck, not so you have to buy a truckload.
Yes. A fine-tooth blade — 8 to 12 teeth per inch, rated for plastic — in a circular, jig, table, or band saw. Clamp the panel to stop vibration, leave the protective film on while cutting, and blow the flutes out with compressed air afterward. Or bring us the measurements and we’ll cut it here.
The UV-protected side, always. It’s marked on the printed polyethylene film and laser-etched into the edge of the sheet. Installing it upside down voids the warranty and the panel will yellow. This is the single most common mistake on a twin wall install.
No. Twin wall is a dry-fit system and Gallina doesn’t recommend sealing inside it. Use 100% silicone only where you flash onto the panel. Silicone and polycarbonate expand at different rates, so a sealed joint eventually pulls apart — and once silicone is on polycarbonate it does not come off.
Out of direct sunlight, dry, and ventilated. Sun bakes the protective film onto the sheet and then it will not come off. If it has to sit outside, cover it — but not with PVC.
Free delivery in Reno, Sparks, Carson City, Fernley and USA Parkway, including the industrial corridor out USA Parkway. Beyond that we quote freight. One sheet or a full pallet, the delivery is the same.
We stock it here and we run our own van. Three ways to get material — take the one you need.
"Best plastic shop in Northern Nevada. Honest people, quality work, been going here for years."
Fill out the form below and we'll get back to you with a quote — most within the same day. Or call us at (775) 358-8211.
Every material and product we carry can be customized with our full range of fabrication services.
Walk into our Sparks shop with your measurements or call us — most quotes returned same day. No minimum order, free delivery in Reno, Sparks, Carson City, Fernley and USA Parkway.